* Connect the live- (L) and the neutral wire (N) to the terminals of the
Marmitek sunblind module.
* Connect the black and the brown wire of the motor connection to
respectively the DN and UP terminal of the sunblind module.
* Connect the blue wire of the motor connection to the neutral wire
connector.
* Connect the yellow/green wire of the motor connection to the earth wire
connector.
* Connect the purple input wire of the sunblind module to the pulse contact
to control Up.
* Connect the white input wire of the sunblind module to the pulse contact
to control Down.
* Connect the grey input wire of the sunblind module to the pulse contact to
control Preset.
* Connect the pink input wire of the sunblind module to the pulse contact to
control Lock.
* Connect the live wire (L) to the P-terminal of the momentary switch.
* Check if the motor’s direction of turning matches with the commands for
Up/Down (Up = ON, Down = OFF). Check this by sending the ON and OFF
commands through the mains to the sunblind module using an interface (for
instance: PRU512, PRU256, CM15Pro). If the direction of turning does not
match the sent commands, then switch the motor connection of the brown
and the black wire on the sunblind module (DN and UP terminal). Then check
if the direction of turning of the motor matches with the operation of the
Up/Down key of the momentary switch. Switch the white and the purple input
wires on the momentary switch if the direction of turning does not match the
operation for Up/Down.