TECHNICAL SPECIFICATIONS
Supply voltage: 230VAC, 50 Hz
Maximal current: 63 A
Central filter frequency: 120 kHz
Bandwidth filter: 5 kHz min. (3 dB points)
Attenuation incoming: 20 dB min. for I = 0 A
15 dB min. for I = 63 A
Attenuation outgoing: 15 dB min.
Input impedance: 20 Ohm min. for f = 120 kHz
Coupling loss: 2 dB max. for f = 120 kHz
Connectors: Screw connectors for phase
(supply), phase (premises), null
and connection.
Surrounding temperature: -10°C to +50°C
(business premises)
-20°C to +70°C
(warehouse)
Measurements: 35x80x65 mm