Simply click the FD10 onto the DIN rail.
Connect the cables as follows:
Phase input to (L)
Null to (N)
Phase output to (L)
Use additional Phase Couplers/Filters for
installations with more than 1 phase. For the complete cou-
pling of three phases you will need three FD10 Phase Cou-
plers/Filters. Connect the filters by connecting connector K
to the following phase (see figure). For this, a 1.5 mm² shift
cable can be used.
Installation diagram
Coupling with filtering Coupling without filtering
Attention: If micro modules are used that can only generate
an X-10 PLC signal at 0 and 180 degrees (such as the
LWM1, TMA4, TMD4 and AWM2), you will only be able to
use the Phase Couplers/Filters as a filter. In order to couple
the phases a CAT3000 will be required.